IT infrastructure calculators

RAID Rebuild Time Calculator

Estimate a RAID rebuild window from disk size, sustained rebuild speed and production load. The URE figure is per-disk unreadable-sector exposure, not the chance of array failure.

Result

Estimated time26.5 hours (1.10 days)
Per-disk URE exposure61.71%

Note: URE is the probability of at least one read error while reading one disk's worth of bits. It is not array-level rebuild risk; array topology and surviving disks read are not modeled. Real rebuilds may be slower.

Learn more

How it works

When a disk fails, the array rebuilds its contents onto a replacement. Time is roughly disk size divided by rebuild speed:

hours = disk size (bytes) / rebuild speed (bytes per second) / 3,600

Production load slows it down: at 30% load, the rebuild gets about 70% of the speed, so the time is divided by 0.7.

URE exposure is the chance of hitting at least one unrecoverable read error while reading one full disk. Drive makers quote a URE rate as 1 error per 1014 or 1015 bits read. The calculator treats errors as random and uses 1 - e-bits read / 10^exponent.

Worked example

The default is a 12 TB disk rebuilding at 180 MB/s under 30% production load, on drives rated 1 URE per 1014 bits:

  • Time: 12,000,000 MB / 180 MB/s = 66,667 s = 18.52 hours at full speed
  • Under 30% load: 18.52 / 0.7 = 26.5 hours (1.10 days)
  • Bits read: 12 x 1012 x 8 = 9.6 x 1013
  • URE exposure: 1 - e-0.96 = 61.71%

The same disk rated at 1015 gives 9.15%. That gap is a big reason RAID 6 is preferred over RAID 5 for large disks.

Worked workflow: compare capacity with the rebuild window

Start with six equal 12 TB disks in RAID 6. The capacity calculator shows 72 TB raw and 48 TB usable, with two-drive failure tolerance under its stated model. Hot spares, filesystem and controller overhead are not included.

Now open RAID Rebuild for one 12 TB replacement disk. At 180 MB/s sustained rebuild speed and 30% production load, the model gives 26.5 hours. With a URE exponent of 14, it reports 61.71% per-disk unreadable-sector exposure. That figure is not the chance the array fails and does not model the controller's recovery behavior.

Use the rebuild estimate to ask whether the degraded window is acceptable. Then plan an independent backup and test restoration. RAID tolerance, a rebuild estimate and a backup-capacity estimate answer different questions.

Is the URE number the chance my rebuild fails?

No. It covers reading one disk. A rebuild reads every surviving disk, and RAID 6 can often correct a read error that would stop a RAID 5 rebuild. Treat it as a way to compare drive ratings, not a failure forecast.

Are URE ratings accurate?

They are spec-sheet limits, and many drives do better in practice. They are still useful for comparing drive classes: desktop drives are usually rated 10^14 and enterprise drives 10^15 or better.

Why is my real rebuild slower?

Controllers often throttle rebuilds to protect production traffic, and SMR drives or heavy random I/O can cut speed a lot. Check the rebuild rate setting on your controller or NAS.

Maintained by the RACKCRUNCH team. Last reviewed October 26, 2026. How we calculate | Report a problem